Ground Fault Monitor

[Contact us for a price]
In stock

The highly configurable Dilithium Design GFM (Ground Fault Monitor) is designed for use in a wide range of Electric Vehicle (EV) systems. The GFM measures the isolation between an electrical system ground and a separate High Voltage (HV) isolated system.

Features:

  • Rapid and accurate isolation measurement
  • Highly configurable
  • Wide voltage range (30-500V)
  • Fault location detection
  • 2x programmable outputs
  • 1x CAN Bus
  • All measurements and information available over CAN bus
  • CAN control of isolation measurement
  • Factory calibrated
  • Built in compatibility with:
    • Dilthium Design MCU
    • Dilthium Design EV Display
    • Fellten CCS Controller

Applications:

  • Automotive EV
  • Marine EV
  • Electric Vehicle Supply Equipment (EVSE)
  • Hybrid Vehicles
  • Energy Storage Systems
General
 Parameter Units Min Typical Max Comments
Weight g   60   Without connectors or harnesses
Environmental Temperature deg C -20 N/A 85  
Overall Dimensions (LxWxH) mm   117 x 59 x 15    
Ingress Protection (IP)     IP30 Equivalent   Protects against small tools and wires, no water protection
Electrical - High Voltage
HV Operational Sense Voltage V 30 N/A 500 Outside of this range measurement will be degraded and isofault condition will be pushed

HV Absolute Voltage

V 0 N/A 600 HV isolation integrity not guaranteed outside this range
Electrical - Low Voltage
Supply Bus Voltage V 9 12 15  
Supply Bus Power mW   300 500